Skip Ribbon Commands Skip to main content

WHAT ARE THE SPECIFICATIONS FOR COMPRESSED AIR FOR MY HURCO MACHINING CENTER  

This article applies to:
VMX24 Machining Center 
VMX42 Machining Center 
VMX50 Machining Center 
VMX64 Machining Center 
VMX30 Machining Center 
VMX60 Machining Center 
VMX84 Machining Center 
VTC 40 

Answer:
The compressed air requirements for my Hurco Machining Center is a continuous supply of clean and dry air is essential for proper machine operation. The following specification must be met:
5 CFM at 80-100 PSI or 0.14 M3/min at 6-8 bar.
It is recommended that you do not use quick coupler type fittings at the connection to the FRL unit, or in the supply line to the machine. These fittings restrict the air supply.
Not in compliance with the above and any damage that is caused may not be covered under Hurco's warranty of normal defects in material and workmanship.

 
 
Bookmark this post with: